Data collection task taking huge time to complete
Hi Team, We are facing an issue in Data collection LDS (load from data stream),and the issue is long time this task was taking approx. 2.30 hrs to complete where as in earlier months it took around 40...
View ArticleCreating custom Column in IDT 4.1
Hi All, I am using SAP IDT 4.1 SP03 to build a business layer over a SQL Server database using relational connection. I having a single table named CUSTOMER and it contains Customer ID, Customer Name,...
View ArticleRe: SMP 3.0 Hyabrid Application
thnx.... actually i am new in SMP. I have been told that i ll be working on SAP mobile platform 3.0. and hybrid applications related. i have no idea where to read and practice
View ArticleRe: UDO Error
hi Eric, Private Sub AddTransUserFields() Dim oUserFieldsMD As SAPbobsCOM.UserFieldsMD Dim iRetcode As Integer '************************************ ' Adding "Name"...
View ArticleTransaction iView - toggle radio button
Hello Experts, I'm using application integrator to run a transaction (WinGUI) from the portal.This is the link I'm using: (P_NPRV is the screen...
View ArticleRe: Qs Stuck up in SMQ2
Try this: Goto SMQR, select all the entries and Deregister them.Wait for about 10 seconds.Select all entries and then Re-register them.See if that helps
View ArticleRe: Meta Process Chain runs red, variant(Sub-chain) stays yellow but chain is...
Hi Somesh/Srinu/Raman, Thanks for the reply, but it din't worked ot I tried doing the above process in SE38 using the program RSPC_PROCESS_FINISH and providing the required inputs. Meta process chain...
View ArticleRe: Do you agree powerdesigner extended models code should be password...
And code crypted :-).
View ArticleRe: Import Default Bin Location Using OITW - ItemWarehouseInfo.xlt
Hi Kennedy, Thanks for you reply. To which PL must I upgrade to enable this functionality? Why does my OITW template show the Default Bin field, see attached screenshot Mias
View ArticleIQ 16: Copy tables with 400 million rows?
Hi everyone, I have an IQ 16 database with 30 tables and about 400 million rows in total. I need to copy these tables together with the rows into another IQ 16 database. What would be the quickest...
View ArticleRe: Relevance of ILOA-OWNER field in table ILOA
My analysis says the Owner field will have values, OWNERDescriptionTriggersEquipment, current time segmentEquipment with Datbi 311299991Equipment, historical time segmentHistorical time2Functional...
View ArticleRe: enhancement spot for updating header text in vf02
Hi You don't need any implicit enhancement in order to update account document while creating the bill: you can use the exit EXIT_SAPLV60B_008: here you can insert your value in structure ACCIT-SGTXT...
View ArticleRe: Sorting of data in prompts/filters
You need to concentrate on Universe end rather than dashboard side, nothing to do with dashboard. Are you talking about custom sorting ?
View ArticleRe: Process of adding a custom field and replication with idoc MDGF
Hi Kiran, Thanks, I am aware of the document but the document describes how the MDG structure is updated - /MDG/SX_0G_CCTR and not how to update structure USMD_E1CSKSM to be able to complete the...
View ArticleRe: Error while triggering IDoc in PI7.4
Hi Neethu, Please see the screenshot attached. We were missing these attributes in our InBoundRA resource adapter and it caused this issue. Please just add them if they are missing in yours. Is under...
View ArticleRe: Any standard field for no.of days?
Dear Geetha, Kindly can you give some more clarity. Ur's Mohan
View ArticleRe: MRP controller in standard network
Danger is cleared. It was the standard WBS who did all the mess (to be specific, it was project profile in std.project definition). It had a wrong plant there. Error description was too abstract to...
View ArticleRe: MDG_S workflow
Hi Abdullah I try to create vendor by assiging WS75700040 and this time it works fine upto step 3 for me mean means I can Agree and do Final Processinf also. In step 4 I am able to approve also but CR...
View ArticleRe: Receiver content conversion
Hi Indrajit, Please have a look at attched fcc parameters screen shot. I have 3 nodes. GROUP comes under first node. Elements of first node are STYPE(mapped constant 0), GROUP (mapped multiple source...
View ArticleRe: Issue with batch determination for MRP area assigned storage locations
Hello PP Guru's,, Please help to resolve this issue Regards Umesh Mali